Eaton Frequency inverters DC1 - 400V

Browse to product table

Interested in buying products?

Want to know more about the prices or order directly? This is possible when you are affiliated with a dealer in your area. Do you want to sell products via Kramp as a dealer? Then sign up!

  • Tailored advice from our specialists
  • More than 500.000 products
  • Up-to-date information on current stock and delivery times

Interested in buying products?

Want to know more about the prices or order directly? This is possible when you are affiliated with a dealer in your area. Do you want to sell products via Kramp as a dealer? Then sign up!

  • Tailored advice from our specialists
  • More than 500.000 products
  • Up-to-date information on current stock and delivery times
Product
Unit

Mains voltage

Number of phases input

Number of phases output

Max. output frequency

Max. output voltage

Nominal output current I2N

Max. output at quadratic load at rated output voltage

Max. output at linear load at rated output voltage

Power consumption

Relative symmetric net frequency tolerance

Relative symmetric net voltage tolerance

Number of analogue outputs

Number of analogue inputs

Number of digital outputs

Number of digital inputs

With control element

Application in industrial area permitted

Application in domestic- and commercial area permitted

Supporting protocol for TCP/IP

Supporting protocol for PROFIBUS

Supporting protocol for CAN

Supporting protocol for INTERBUS

Supporting protocol for ASI

Supporting protocol for KNX

Supporting protocol for Modbus

Supporting protocol for Data-Highway

Supporting protocol for DeviceNet

Supporting protocol for SUCONET

Supporting protocol for LON

Supporting protocol for PROFINET IO

Supporting protocol for PROFINET CBA

Supporting protocol for SERCOS

Supporting protocol for Foundation Fieldbus

Supporting protocol for EtherNet/IP

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for DeviceNet Safety

Supporting protocol for INTERBUS-Safety

Supporting protocol for PROFIsafe

Supporting protocol for SafetyBUS p

Supporting protocol for BACnet

Supporting protocol for other bus systems

Number of HW-interfaces industrial Ethernet

Number of interfaces PROFINET

Number of HW-interfaces RS-232

Number of HW-interfaces RS-422

Number of HW-interfaces RS-485

Number of HW-interfaces serial TTY

Number of HW-interfaces USB

Number of HW-interfaces parallel

Number of HW-interfaces other

With optical interface

With PC connection

Integrated breaking resistance

4-quadrant operation possible

Type of converter

Insulation class

Height

Width

Depth

Manufacturer Product ID

Max. Current (A)

Max. motor rating

Output Frequency (Hz)

Number of phases input

Number of phases output

Suitable for original number

Protection class

Primary power supply (V)

Each
380.0-480.0 V
3
3
500 Hz
500 V
4,1 A
1,5 kA
1,5 kA
76,5 VA
10 %
10 %
1
2
1
4
Yes
Yes
Yes
No
No
Yes
No
No
No
Yes
No
No
No
No
No
No
No
No
Yes
No
No
No
No
No
No
Yes
0
0
0
0
1
0
0
0
0
No
Yes
No
No
U converter
20
184 mm
81 mm
124 mm
185746
4.1 A
1.5 kW
50/60 Hz
3
3
DC1-344D1FN-A20CE1
IP20
400V
Each
380.0-480.0 V
3
3
500 Hz
500 V
5,8 A
2,2 kA
2,2 kA
101,2 VA
10 %
10 %
1
2
1
4
Yes
Yes
Yes
No
No
Yes
No
No
No
Yes
No
No
No
No
No
No
No
No
Yes
No
No
No
No
No
No
Yes
0
0
0
0
1
0
0
0
0
No
Yes
Yes
Yes
U converter
20
231 mm
107 mm
152 mm
185752
5.8 A
2.2 kW
50/60 Hz
3
3
DC1-345D8FB-A20CE1
IP20
400V
Mains voltage (volt)
Number of phases input
Number of phases output
380.0-480.0
3
3
Mains voltage (volt)
Number of phases input
Number of phases output
380.0-480.0
3
3