Details | - Not suitable for oil or fuel
- Installation behind the three-way valve
- A distance corresponding to 5 times the diameter in front of the flow meter and 2 times the diameter behind the flow meter must be absolutely horizontal in order to prevent turbulence
| |
---|
Application range | - Liquid manure dosing system
- Other conductive liquids
| |
---|
Properties | - The Optiflux 1000 with the IFC100 amplifier is an inductive flowmeter without moving parts. The flowmeter measures the flow using a generated magnetic field and the conductance of the liquid
-
- The IFC100 amplifier can be set up in different ways, e.g. for direct current or voltage output signal
| |
---|
Consists of | - Optiflux 1000 flowmeter
- IFC100 amplifier
- Without flange!
| |
---|
Technical info | - Measuring principle: Faraday's Law
- Primary measuring value: flow speed
- Secondary measuring values: flow volume, flow mass, electrical conductance, coil temperature
- Measuring range: -12 to +12 m/s (-40 to +40 ft/s)
- Temperature of the medium to be measured: -40 to +180 C
- Ambient temperature: -40 to +65°C
- Calibration in accordance with EN17025
| |
---|
Benefits | - Maintenance-free
- Very versatile
- Very long service life
| |
---|