Equalising valves or brake valves provide controlled movement, stopping and holding of loads. They prevent the lag of movements (negative load) and protect the installation against external forces (anti-shock). Overcentre valves provide controlled initiation and stopping of a movement, while holding the load at rest. When mounted directly on the cylinder or motor, they also function as hose breakage protection.
Show more
Pros
  • Provides gentle, controlled movements
  • Load-holding valve
  • Hose breakage protection
  • Protects against pressure peaks caused by external forces
  • Prevents lag caused by negative loads
  • Protects consumer against cavitation
Product details
  • HV: Hydraulically released spring chamber; A, B and T must be connected to each other in the neutral position
  • Pressure setting must be approx. 30% higher than the maximum load pressure
  • High return pressure can impair valve operation
  • Line installation as close to the consumer as possible
  • Free flow from 2 to 1
  • Opening pressure depends on pressure setting, load pressure and control pressure ratio
Includes
  • Cartridge
  • Excl. housing
Browse to media

Interested in buying products?

Want to know more about the prices or order directly? This is possible when you are affiliated with a dealer in your area. Do you want to sell products via Kramp as a dealer? Then sign up!

  • Tailored advice from our specialists
  • More than 500.000 products
  • Up-to-date information on current stock and delivery times
Product
Unit

Designed for

Flow rate

Pressure max.

Opening pressure spring (bar)

Note

Pilot ratio

Pressure range

Seal

Size

B

A (mm)

Torque Nm

Pilot ratio

SW1

Each
As a safety component when, in single or double action systems, cylinders or motors must remain fixed in any desired position. External forces may not affect the position.
60 l/min
350 BAR
1
Stable, quiet and precise function. The value set should always be 30% higher than the maximum load pressure.
1:10
110 - 350 BAR
Order no.: with code CP 9-4.10.006
SDC 10-3S Inch
Each
As a safety component when, in single or double action systems, cylinders or motors must remain fixed in any desired position. External forces may not affect the position.
60 l/min
350 BAR
1
Stable, quiet and precise function. The value set should always be 30% higher than the maximum load pressure.
1:3
35 - 110 BAR
Order no.: with code CP 9-4.10.006
SDC 10-3S Inch
Each
As a safety component when, in single or double action systems, cylinders or motors must remain fixed in any desired position. External forces may not affect the position.
60 l/min
350 BAR
1
Stable, quiet and precise function. The value set should always be 30% higher than the maximum load pressure.
1:4,5
55 - 180 BAR
Order no.: with code CP 9-4.10.006
SDC 10-3S Inch
Each
As a safety component when, in single or double action systems, cylinders or motors must remain fixed in any desired position. External forces may not affect the position.
60 l/min
350 BAR
1
Stable, quiet and precise function. The value set should always be 30% higher than the maximum load pressure.
1:4,5
75 - 240 BAR
Order no.: with code CP 9-4.10.006
SDC 10-3S Inch
Each
As a safety component when, in single or double action systems, cylinders or motors must remain fixed in any desired position. External forces may not affect the position.
57 l/min
345 BAR
1
Stable, quiet and precise function. The value set should always be 30% higher than the maximum load pressure.
69 - 241 BAR
Order no.: with code CP 9-4.10.006
CP10-3L Inch
52.3 mm / 52.30 mm
92.2 mm
47 - 54 N·m
1 : 4,5
25.4 mm
Each
As a safety component when, in single or double action systems, cylinders or motors must remain fixed in any desired position. External forces may not affect the position.
57 l/min
345 BAR
1
Stable, quiet and precise function. The value set should always be 30% higher than the maximum load pressure.
103 - 345 BAR
Order no.: with code CP 9-4.10.006
CP10-3L Inch
52.3 mm / 52.30 mm
92.2 mm
47 - 54 N·m
1 : 4,5
25.4 mm
Designed for
Flow rate (litre per minute)
Pressure max. (bar)
As a safety component when, in single or double action systems, cylinders or motors must remain fixed in any desired position. External forces may not affect the position.
60
350
Designed for
Flow rate (litre per minute)
Pressure max. (bar)
As a safety component when, in single or double action systems, cylinders or motors must remain fixed in any desired position. External forces may not affect the position.
60
350
Designed for
Flow rate (litre per minute)
Pressure max. (bar)
As a safety component when, in single or double action systems, cylinders or motors must remain fixed in any desired position. External forces may not affect the position.
60
350
Designed for
Flow rate (litre per minute)
Pressure max. (bar)
As a safety component when, in single or double action systems, cylinders or motors must remain fixed in any desired position. External forces may not affect the position.
60
350
B (millimetre)
Designed for
Flow rate (litre per minute)
52.3
52.30
As a safety component when, in single or double action systems, cylinders or motors must remain fixed in any desired position. External forces may not affect the position.
57
B (millimetre)
Designed for
Flow rate (litre per minute)
52.3
52.30
As a safety component when, in single or double action systems, cylinders or motors must remain fixed in any desired position. External forces may not affect the position.
57

Media (1)