Motor-protective circuit-breaker, PKZM01

Browse to product table

Interested in buying products?

Want to know more about the prices or order directly? This is possible when you are affiliated with a dealer in your area. Do you want to sell products via Kramp as a dealer? Then sign up!

  • Tailored advice from our specialists
  • More than 500.000 products
  • Up-to-date information on current stock and delivery times
Technical info
  • The PKZ motor-protective circuit-breaker from Moeller is synonymous with quality.
  • Moeller is reintroducing the popular pushbutton actuation in addition to the rotary drive with the new xStart product system for the PKZM 01 (up to 16 A). Furthermore, the PKZ motor-protective circuit-breaker has been modified and its technical performance improved.
  • Just as certain as the clear indication of the switch positions in the PKZ series is the secure handling of short-circuit currents: The PKZM 0 and PKZM 4 devices master currents up to 150 kA.

Interested in buying products?

Want to know more about the prices or order directly? This is possible when you are affiliated with a dealer in your area. Do you want to sell products via Kramp as a dealer? Then sign up!

  • Tailored advice from our specialists
  • More than 500.000 products
  • Up-to-date information on current stock and delivery times
Product
Unit

Adjustment range undelayed short-circuit release

Insulation class

Depth

Device construction

Height

Number of poles

Overload release current setting

Phase failure sensitive

Rated operating voltage

Rated operation power at AC-3, 400 V

Rated permanent current Iu

Rated short-circuit breaking capacity lcu at 400 V, AC

Switch off technique

Type of control element

Type of electrical connection of main circuit

Width

With integrated auxiliary switch

With integrated under voltage release

With thermal overload protection

Manufacturer Product ID

Overload release current setting

Rated operation power at AC-3, 230 V

Rated operation power at AC-3, 440 V

Rated permanent current Iu

Rated operation power at AC-3, 230 V

Each
6.2-6.2 A
20
93 mm
Built-in device fixed built-in technique
90 mm
3
0.250-0.4 A
Yes
690.0-690.0 V
0,09 kW
0,4 A
50 kW
Thermomagnetic
Push button
Screw connection
45 mm
No
No
No
278477
0,25 A
0,06 kW
0,12 kW
0,4 A
Each
15.5-15.5 A
20
93 mm
Built-in device fixed built-in technique
90 mm
3
0.630-1.0 A
Yes
690.0-690.0 V
0,25 kW
1 A
50 kW
Thermomagnetic
Push button
Screw connection
45 mm
No
No
No
278479
0,63 A
0,12 kW
0,25 kW
1 A
Each
25.0-25.0 A
20
93 mm
Built-in device fixed built-in technique
90 mm
3
1.0-1.6 A
Yes
690.0-690.0 V
0,55 kW
1,6 A
50 kW
Thermomagnetic
Push button
Screw connection
45 mm
No
No
No
278480
1 A
0,25 kW
0,55 kW
1,6 A
Each
39.0-39.0 A
20
93 mm
Built-in device fixed built-in technique
90 mm
3
1.6-2.5 A
Yes
690.0-690.0 V
0,75 kW
2,5 A
50 kW
Thermomagnetic
Push button
Screw connection
45 mm
No
No
No
278481
1,6 A
0,37 kW
1,1 kW
2,5 A
Each
62.0-62.0 A
20
93 mm
Built-in device fixed built-in technique
90 mm
3
2.5-4.0 A
Yes
690.0-690.0 V
1,5 kW
4 A
50 kW
Thermomagnetic
Push button
Screw connection
45 mm
No
No
No
278482
2,5 A
0,75 kW
1,5 kW
4 A
Each
98.0-98.0 A
20
93 mm
Built-in device fixed built-in technique
90 mm
3
4.0-6.3 A
Yes
690.0-690.0 V
2,2 kW
6,3 A
50 kW
Thermomagnetic
Push button
Screw connection
45 mm
No
No
No
278483
4 A
1,1 kW
3 kW
6,3 A
1,1 kW
Each
155.0-155.0 A
20
93 mm
Built-in device fixed built-in technique
90 mm
3
6.3-10.0 A
Yes
690.0-690.0 V
4 kW
10 A
50 kW
Thermomagnetic
Push button
Screw connection
45 mm
No
No
No
278484
6,3 A
2,2 kW
4 kW
10 A
2,2 kW
Each
186.0-186.0 A
20
93 mm
Built-in device fixed built-in technique
90 mm
3
8.0-12.0 A
Yes
690.0-690.0 V
5,5 kW
12 A
50 kW
Thermomagnetic
Push button
Screw connection
45 mm
No
No
No
278485
8 A
3 kW
5,5 kW
12 A
3 kW
Each
248.0-248.0 A
20
93 mm
Built-in device fixed built-in technique
90 mm
3
10.0-16.0 A
Yes
690.0-690.0 V
7,5 kW
16 A
50 kW
Thermomagnetic
Push button
Screw connection
45 mm
No
No
No
283390
10 A
4 kW
9 kW
16 A
4 kW
Each
388.0-388.0 A
20
93 mm
Built-in device fixed built-in technique
90 mm
3
20.0-25.0 A
Yes
690.0-690.0 V
12,5 kW
25 A
50 kW
Thermomagnetic
Push button
Screw connection
45 mm
No
No
No
288893
20 A
5,5 kW
12,5 kW
25 A
5,5 kW
Adjustment range undelayed short-circuit release (ampere)
Insulation class
Depth (millimetre)
6.2-6.2
20
93
Adjustment range undelayed short-circuit release (ampere)
Insulation class
Depth (millimetre)
15.5-15.5
20
93
Adjustment range undelayed short-circuit release (ampere)
Insulation class
Depth (millimetre)
25.0-25.0
20
93
Adjustment range undelayed short-circuit release (ampere)
Insulation class
Depth (millimetre)
39.0-39.0
20
93
Adjustment range undelayed short-circuit release (ampere)
Insulation class
Depth (millimetre)
62.0-62.0
20
93
Adjustment range undelayed short-circuit release (ampere)
Insulation class
Depth (millimetre)
98.0-98.0
20
93
Adjustment range undelayed short-circuit release (ampere)
Insulation class
Depth (millimetre)
155.0-155.0
20
93
Adjustment range undelayed short-circuit release (ampere)
Insulation class
Depth (millimetre)
186.0-186.0
20
93
Adjustment range undelayed short-circuit release (ampere)
Insulation class
Depth (millimetre)
248.0-248.0
20
93
Adjustment range undelayed short-circuit release (ampere)
Insulation class
Depth (millimetre)
388.0-388.0
20