12 V shut-off solenoid

Browse to product table

Interested in buying products?

Want to know more about the prices or order directly? Sign up for an online account today or visit your local dealer.

  • Tailored advice from our specialists
  • Next-day delivery*
  • More than 500.000 products
Details
  • With thermal fuse to protect the induction coil
  • Stop magnet must be able to perform a complete stroke, otherwise the thermal fuse is actuated
Application range
Combustion engines
Properties
Stop magnet for interrupting fuel supply
Consists of
Stop magnet with assembly foot and 180 mm connecting cable
Technical info
  • Power supply: 12 V
  • Withdrawal current: 41 Ampere
  • Withdrawal current: 0.5 Ampere
  • Maximum stroke length: 40 mm
  • Force at 4 mm: 100 N
  • Force at 25 mm: 66 N
  • Force at 40 mm: 43 N
  • Weight: 1180 g
  • Red cable: +12 V from the input coil
  • Blue cable: +12 V from the stop coil
  • Housing: earth
Benefits
  • Automatic switching from induction to stop coil
  • Insulated design

Interested in buying products?

Want to know more about the prices or order directly? Sign up for an online account today or visit your local dealer.

  • Tailored advice from our specialists
  • Next-day delivery*
  • More than 500.000 products
Product
Unit

Consists of

Note

Voltage

Each
Stop magnet with assembly foot and 180 mm connecting cable
Max. strokelength = 40mm / Pull current = 41 A / Hold current = 0,65A / Strength at 4 mm stroke = 100 N / Strength at 25 mm stroke = 66 N / Strength at max. stroke 40 mm = 43 N / Weight = 1,18 Kg
12 V
Consists of
Note
Voltage (volt)
Stop magnet with assembly foot and 180 mm connecting cable
Max. strokelength = 40mm
Pull current = 41 A
Hold current = 0,65A
Strength at 4 mm stroke = 100 N
Strength at 25 mm stroke = 66 N
Strength at max. stroke 40 mm = 43 N
Weight = 1,18 Kg