Accumulator charging valve, type AV02

Browse to product table

Interested in buying products?

Want to know more about the prices or order directly? Sign up for an online account today or visit your local dealer.

  • Tailored advice from our specialists
  • Next-day delivery*
  • More than 500.000 products
Long description
A loading valve, also called unloading valve or constant pressure valve, provides a constant set pressure in a secondary system. Preferably in combination with an accumulator. This valve opens at 15% pressure difference from the set pressure and relieves the pump to the return. The check valve will keep port U pressurised and the coupled accumulator will absorb pressure fluctuations or sudden volume demand in the secondary system.
Show more
Product details
  • Set to 30 bar
  • Pressure difference between switching on and off: 15%
Includes
  • Housing
  • Directly controlled pressure relief valve
  • Pressure reducing valve
  • Check valve
  • Shuttle valve

Interested in buying products?

Want to know more about the prices or order directly? Sign up for an online account today or visit your local dealer.

  • Tailored advice from our specialists
  • Next-day delivery*
  • More than 500.000 products
Product
Unit

Max. flow rate

Max working pressure

Connection type

Connection thread type

Connection thread diameter

Connection 2, thread type

Housing length

Housing width

Housing height

Total height

Mounting holes diameter

Extra info

Each
20 l/min
350 BAR
Thread
Inch
1/4 Inch
Metric
59 mm
38.5 mm
90 mm
169.4 mm
10 mm
L1 + L2 = Tank connection / P1 + P2 = Pump connection / V1 + V2 = Work port connection
Max. flow rate (litre per minute)
Max working pressure (bar)
Connection type
20
350
Thread